Characterization of micro and nanoparticles by the method of dynamic and electrophoretic light scattering

Zetasizer Ultra (Malvern Panalytical)- the latest generation

Instrument for measurement of the particle size, zeta potential and concentration of micro and nanoparticles and molecules in dispersion or suspension

Financed by HRZZ Project UIP-2017-05-7337

The Zetasizer Ultra (Malvern Panalytical) instrument provide the ability to:

  • measure the size, size distribution, charge and concentration of micro and nanoparticles
  • studies of dispersions stability
  • optimization of nanoparticle synthesis
  • characterization of model membranes (liposomes, micelles)
  • characterization of polymers solutions, proteins
  • etc

Year of manufacture: 2018.

Instrumental features:

Principle of work: dynamic and electrophoretic light scattering

Light source: 632.8 nm red laser, He-Ne 10 mW

Multi-Angle Dynamic Light Scattering (MADLS): foward (13°),  side (90°) and back (173°) scattering

Particle size: measuring range: 0.3 nm – 10 μm

Minimum sample volume: 3 μL

Zeta potential: measuring range: no limitations;    minimum sample volume: 20 mL

Maximum sample conductivity: 260 mS/cm

 Additional characteristics:

Multi-Angle Dynamic Light Scattering (MADLS): 3 detection angles → individual results as well as an unique result of all scattering angles → real image of the sample

ZS Xplorer software: a) Quality guidance system, automatic advice how to improve measurement; b) Adaptive Correlation: automatically adjust parameters, shorter measurement duration, more sub-runs → intelligent data: reliable and repeatable data → representative view of the sample

Particle concentration: measuring range: 1´108 - 1´1012 particles/mL

Determination of concentration without previous calibration

Possibility of showing the total concentration of particles and the concentration of particles in a given distribution

Temperature control range: 0 - 120 °C

Variable measurement positioning inside cuvette

Fluorescence filter; Horizontal and vertical polarizers - the ability to distinguish translational from rotational diffusion – for anizotropic particles (rods, nanotubes...)

Contact:

Tanja Jurkin, dr.sc.

Senior research associate
Tel:
+385 1 457 1255
Interni broj:
1576
Authorized users:

Dr. Tanja Jurkin (responsible person)

mag. chem.Ivan Marić

Dr. Anđela Pustak

This site uses cookies.. Some of these cookies are essential, while others help us improve your experience by providing insights into how the site is being used. For more detailed information on the cookies we use, please check our Privacy Policy.

Customise settings
  • Necessary cookies enable core functionality. The website cannot function properly without these cookies, and can only be disabled by changing your browser preferences.